Carbon paste electrode doped with selenium powder(SeCPE)was fabricated by doping graphite powder,selenium powder and paraffin with a certain proportion.The SeCPE sensor was used to determine Sb~(3+)by differential pulse stripping voltammetry(DPV).A maximum peak current efficiency of Sb~(3+) was obtained with the SeCPE sensor which was doped with 20%Se powder and immersed in 0.36 mol/L hydrochloric acid solution following a 60 sdeposition time at-0.45V.The linear relationship between the peak current and antimony concentration was found in the r...