The research group utilized the estimation model of energy consumption capacity for reinforced concrete components without axial force to assess the energy consumption capacity of 92-reinforced concrete components from the PEER database, which were subjected to axial force and bending. The study also examined the impact of design parameters, including longitudinal reinforcement ratio, transverse reinforcement ratio, axial compression ratio, and shear-span ratio, on the estimation results. The research findings revealed that when applying the es...